Information Name: | Factory direct dual power |
Published: | 2013-04-06 |
Validity: | 30 |
Specifications: | LCQ1M |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | ATS also said ATSE abbreviation for Automatic transfer Switching equipment, the national standard Chinese called the Automatic Transfer Switching Equipment, commonly known as dual power automatic transfer switch. ATS GB standard defined by one (or several) transfer switching equipment and other necessary electrical components for detecting the power supply circuit, and one or more load circuit from a power supply automatically converted to another electrical power. ATS and UPS, EPS in the name of confusing. EPS Emergency Power Supply abbreviation, the Chinese called the emergency power unit. UPS Uninterruptible Power Supply abbreviation, the Chinese called uninterruptible power supply. ATS (ATS) is the acronym for Automatic Transfer Switching Equipment, the Chinese called automatic transfer switching equipment. ATS suitable for dual power supply used in the construction field fire load, EPS EPS is suitable for a load of power supply equipment such as emergency lighting, emergency lighting, fire-fighting facilities as the main target, a line with the Fire Code emergency power supply system of independent loops. UPS equipment for the IT industry to provide electricity to provide clean, uninterrupted power backup. Diesel generator power supply suitable for use in place with ATS need back-up power for a long time the power supply, EPS, UPS used in conjunction with. Operating procedures, when for some reason the power outage, and in a relatively short period of time can not restore power must be enabled standby power. Steps: (1) removal of the mains power supply circuit breaker (including power distribution room control cabinet circuit breaker, dual power supply breaker switch box City), opened the double-throw switch to a self-powered side of anti send down, maintained a double- Power switch box captive power supply circuit breaker in the off state. (2) start the standby power (diesel generator sets), the normal operation of the standby group, the order of closed the generator air switch-owned power control cabinet circuit breaker. ③ closed one by one power switch inside the standby power circuit breakers, power transmission to the load. ④ standby power during operation, the operator on duty shall not leave the generator set and adjust the voltage under load changes in a timely manner, plant frequency, abnormal timely manner. 2, when the mains power is restored, you should do a good job in a timely manner the power conversion, cut off the standby power, restore electricity supply. Steps: (1) one by one in order to disconnect the self-powered breaker, the order is: dual power switching box-owned power circuit breaker →-owned power distribution cabinet breaker → generator switch → double-throw switch to the City power supply side. (2) by the diesel engine shutdown procedure downtime. ③ in order, from the mains power supply master switch to the shunt switch one by one, each circuit breaker is closed, the dual power switching box from the mains power supply circuit breaker in the closed position. 3, check the instrument and indicator indicates whether normal startup transformer cooling fan. Edit this paragraph categories dual power automatic transfer switch (hereinafter referred to as dual power) 1, PC-class integrated excitation switch is a state-of-the-art in the many ATS. CB level, the use of two types of molded case circuit breakers and load switch Products dual power as the implementation of components, together with the microcontroller core of the automatic controller and control mechanism with mechanical and electrical interlocking is a perfect performance, safe, reliable, high degree of automation, the use of a wide range of dual power automatic transfer switch. This product is suitable for AC 50/60Hz, 690V and below, rated current from 6A to 1250A and two-way power supply system of the (common power N and backup power supply or generator power R), due to the way the power failure ( power outage, undervoltage, overvoltage, phase failure, frequency offset) between the power supply automatically switches to ensure the reliability and security of supply. Widely used in high-rise buildings, residential, hospitals, airports, docks, fire, metallurgy, chemical, textile and other important places of power does not allow dual power switch, the unattended continuous power supply. The schematic overview Dual Power Automatic Transfer ◆ a composite double row contact, cross-connected institutions, micro-motor pre-storage and microelectronic control technology, the basic realization of the zero-arcing (without breaking the cover) ◆ reliable mechanical interlock and electrical interlock technology ◆ zero Technical ◆ has significantly off position indicator, the padlock function, reliable power source and the load isolation between high reliability, service life of more than 8000 times ◆ mechatronic design, switching converters accurate, flexible and reliable electromagnetic compatibility, anti-interference ability, without external interference, high automation ◆ Automatic any control components without external appearance, small size, light weight by the logic control panel to manage different logic directly mounted on the switch within the motor, gearbox Activity line operation to ensure that the position of the switch. Motor for the the neoprene insulation hot and humid motor equipped with safety devices, trip beyond 110 ° C humidity and over-current state. Work automatically as soon as the fault disappears, reversible reduction gear spur. On the Haida Electric, specializing in the production of dual power, dual power switch, dual power switch, cool power automatic transfer switch, dual power automatic switch, dual power automatic switching device, dual power switch, LKB0 control and protective switching, CM1 plastic case circuit breaker, C45 miniature circuit breakers, inverter, surge protectors, Tel 13736387321, welcome new and old customers to inquire. |
Admin>>>
You are the 19144 visitor
Copyright © GuangDong ICP No. 10089450, Haida force electrical sticks Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 19144 visitor
Copyright © GuangDong ICP No. 10089450, Haida force electrical sticks Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility